DL5000-CCL
Modbus/ASCII Interface to CC-Link
The DL5000-CCL Communicator enables Modbus and Generic Data (ASCII) serial application protocols to exchange data with CC-Link devices and networks. The DL5000 Communicator is an external DIN rail device that connects CC-Link networks to serial interface devices and networks using standard connectors.
The DL5000-CCL enables PCs, PLCs and MMIs as well as OEM equipment such as bar-code readers, printers, scales, process control devices etc., to connect to CC-Link devices and networks.
The Communicator is fully configurable through a user-friendly Windows configuration program that enables a PC to configure certain fieldbus parameters as well as all serial sub-network properties.
Features:
- Din rail mountable (or free-standing) in small footprint
-
Up to 1024 bytes of I/O data storage (512 Input and 512 Output)
-
Serial interface selections RS232, RS422 and RS485
- Modbus RTU Master and Generic Data (ASCII) modes
- Multi-drop up to 31 serial devices
- Generic Data mode for both solicited or unsolicited messaging
- PC-software for easy configuration
- Switches for setting fieldbus node address (where applicable)
- UL, cUL and CE approved
Specifications:
Mechanical Dimensions: 4.75" x 3" x 1.1"
oooo (120mm x 75mm x 27mm)
Power Supply: 24 V DC (300mA max)
Operating Temperature: 0-70 deg C
Mechanical rating: IP20 |
CC-Link baud rates: 156 Kbaud to 10 Mbaud
Serial network baud rate: Up to 57.6 Kbaud
Serial Interface: RS232, RS422 and RS485 (software selectable)
Order Code: DL5000-CCL |
|
|