DL2000-K2F
Dual Port - DF1 to DH+ Controller

The DataLink DL2000-K2F connects two serial devices using A-B serial DF1 Protocol to a single Allen-Bradley Data Highway Plus. This unit is similar to having two A-B 1770-KF2s or two DL2000-KFXs in a single enclosure and each serial port has its own DH+ station address. The primary serial port is configured for any DH+ station number (base address) is capable of serial communications of up to 115.2 Kbaud (RS232 or RS422 / RS485), Point-to-Point (full-duplex) or Multi-drop (half-duplex), and can be set to use Handshaking. The second serial channel is automatically configured to the next higher DH+ station address and is capable of serial communications of up to 38.4 Kbaud (RS232 or RS422) and Point-to-Point, no Handshaking. Both serial ports must use the same message check method (either BCC or CRC) and share common DF1 protocol parameters such as Execute or Pass Diagnostic command.

Two Serial Ports in One Unit:
Second interface increases DH+ accessibility

Compact and Lightweight:
Small size for installation convenience and portability

Flexible Serial Interfacing:
RS232C and RS422/RS485

Easy Configuration:
All parameters are menu-driven

Increased Throughput:
Serial and DH+ communications at speeds up to 115.2 Kbaud

Specifications:

Interfaces
Channel A: Synchronous; SDLC Transformer-coupled
Channel B: Asynchronous; RS232C/RS422/RS485
Channel C : Asynchronous; RS232C/RS422/RS485

Physical Dimensions
Size: 7.5" D x 5.5" W x 1.5" H
(190mm x 140mm x 38mm)
Weight: 2.2lbs (1kg.)

Power
AC: 110/220 VAC (+/- 25%); 50/60 Hz; 5 Watts
DC: 10 - 35 VDC; 5 Watts

Installation
Freestanding; Metal enclosure

Environment
Operating: +32 F to 122 F (0 C to +50 C)
Storage: -40 F to +185 F (-40 C to +85 C)
Humidity: 5% to 95% non-condensing

Protocols
Channel A: Allen-Bradley Data Highway Plus
Channel B: Allen-Bradley DF1 (ANSI X3.28)
Channel C: Allen-Bradley DF1 (ANSI X3.28)

Configuration
PC program software menu for communications parameters
Selection
Jumpers select supply voltage and serial interface type

Indicators
1 LED for power-on; 5 LEDs for communications activity

Switches
Reset and Configure/Diagnostics mode pushbuttons

Error Detection
Channel A: CRC
Channel B & C: BCC or CRC

Communications
Channel A: Synchronous, DH+ at
57.6 Kbaud
Channel B: Asynchronous; 300 baud
to 115.2 Kbaud
Channel C: Asynchronous; 300 baud
to 38.4 Kbaud

Hardware
Z180 Processor; 32 Kbyte socketed EPROM;
32 Kbyte RAM; 256 byte EEPROM;
1 DH+ and 2 serial interface connectors

 

 