Welcome to DataLink Technologies Group, Inc!
 
 
DataLink Technologies Group, Inc. provides (AB) Allen Bradley PLC users with Ethernet and serial (DF1, ASCII, Modbus) gateways to AB Data Highway Plus (DH+), DH-485 & Remote I/O. At DataLink, we design and implement solutions for your application.

We have a family of “DL” standardized, off the shelf, Ethernet TCP/IP, Ethernet IP, DH+, DH-485 and Remote I/0 products. Our engineers also like to customize such networks for your application. As Ethernet is growing in popularity, we can now customize your serial DF1, ASCII, Modbus, and custom protocols to AB Ethernet, Ethernet/IP; as well as the legacy DH+, DH-485, Remote I/O applications.

 
  New  Products   Overview
Call or email for any technical support issues
or pricing inquiries





Toll free (866) 709-6390
or
(604) 632-4278
(9:00am EST)
Ethernet IP to Allen Bradley DH+/DH-485
DL3500-DH+/IAP
DF1 to DH+ Network
DL3500-DH+/DF1
Ethernet TCP/IP to DH+
DL4500-EDH+
 "We do the Talking"

Sign up for our monthly
newsletter and we’ll alert you to new DataLink solutions, technologies, developments site features!

        
        DataLink Product Index
   

DL4500-EDH+
Ethernet TCP/IP to DH+

   

DL4500-EDH-485
Ethernet TCP/IP to DH-485

   

DL4500-MEDH+
Modbus TCP/IP to DH+

   

DL4500-MEDH-485
Modbus TCP/IP to DH-485 

 
 

DL4500-MEDH-485
Modbus TCP/IP to DH-485 

   

DL3500-DH+/Ascii
Ascii Devices to DH+

   

DL3500-DH-485/Ascii
Ascii Printers / Scanner to DH-485

   

DL3500-DH+/DF1
DF1 Protocol to Data Highway Plus

   

DL3500-DH-485/DF1
DF1 Protocol to DH-485

   

DL3500-DH+/Modbus
Modbus DH+

   

DL3500-DH-485/Modbus
Modbus DH-485

   

DL3500-DH+/Ethernet IP
EtherNet IP Master to PLC on DH+ as Slave

   

DL3500-DH+/IAP
EtherNet IP Master to PLC on DH+ as Slave

   

DL3500-DH-IAP
DH+ Master to PLC on Ethernet Slave

   

DL-PC
ISA Bus Interface

    DL-PCI
PCI Bus Interface
   

DL-PC104
PC/104 Bus Interface

   

DL2000-ASM
DH+ Printer

   

DL2000-CMX
Modbus DH+

   

DL4000-DAS
Interface bi-directional ASCII to DF1

   

DL4000-DFX
DF1 Port Expander

   

DL4000-DMX
DF1 to Modbus MASTER/SLAVE Interface

   

DL4000-MAS
Interface Modbus RTU Master to ASCII

   

DL4000-MMX
Modbus MASTER RTU to Modbus SLAVE ASCII Interface

    DL4000-PWM
AB Power Monitor 3000 to Modbus
    Gateways to Data Highway Plus (DH+)
   

Gateways to Data Highway 485 (DH-485)

Traditional applications include: DF1, ASCII & Modbus interfaces to AB's Data Highway Plus (DH+) & DH485. DataLink’s more cost efficient and reliable solutions include replacements to 1770-KF2, 1770-KF3,1784-KTX, 1784-PKTX, 1784-PCMK and SST 5136-SD products.

Newer applications include: Ethernet TCP/IP, AB Ethernet/IP, ControlLogix , Compactlogix, Micrologix, & SLC 5/05 interfaces to legacy AB Data Highway Plus (DH+), DH-485 and Remote I/O.

HMI & SCADA Applications: RSLinx, RSLogix, Wonderware, Siemens Win CC, Modicon Concept, Citect, Kepware, Intellution FIX can now interface between Ethernet TCP IP, ModTCP, & AB Ethernet IP to Legacy AB DH+, DH485 and RIO.

DataLink Solutions for your Application:

Q: I just bought a new PC and discovered that it has a smaller PCI slot that the 1784-PKTx card doesn't support.  Can you help me out?

A:
DataLink can provide an external, palm-sized, USB DL3500 controller to solve that problem. Our products are: DL3500-DH+/DF1 and DL3500-DH-485/DF1.


Q: We are looking for a system to take some downtime information off of several Micrologix PLCs and link them to a SLC 5/04 PLC

A:
We have two possible solution for this application:
DL3500-DH+/DF1: This solution will enable the Micrologix via Channel 0 (DF1) to become a node on DH+.

DL3500-DH+/IAP: This solution will allow the Micrologix (AB Ethernet) to access the nodes on DH+.


Q: I would like to interface my Modbus TCP/IP Network to AB’s Data Highway Plus DH+ so I extend the life of my PLCs without upgrading each processor to Ethernet. Do you have a product that will do this?

A:
Yes, our DL4500-MEDH+ and DL4500-MEDH-485 allows applications such as RSLogix, RSLinx, and RSView to access devices on a DH+ network from an Ethernet/IP LAN, enabling users to run MMI applications or program and monitor PLCs on a DH+ network from an Ethernet LAN station. Other MMI’s tested include Wonderware, Kepware, and Intellution


Q: Why would I go with your DL3500-DH+/IAP (Ethernet/IP gateway to DH+) instead of upgrading all my AB Equipment (ie. PLC5s) to Ethernet/IP?

A:
Cost. You only need one DL3500-DH+/IAP per DH+. You don't have to upgrade each PLC5 processor on DH+ to a PLC5E . This can save significant money if you have a big DH+ Network. This functionality allows RSLinx/RSLogix on Ethernet/IP have access to all the nodes on your DH+. More About the IAP: DataLink now offers the DL3500-DH+/IAP package that significantly reduces your AB Ethernet upgrading costs as you don't need to replace each DH+ PLC processor/device. Simply make the DL3500-DH+/IAP a node on DH+ and then interface to your AB Ethernet. AB PLC users can interface bi-directionally between Allen-Bradley Data Highway Plus (DH+) / DH-485 and AB Ethernet (CIP & 2222 protocols). AB Ethernet (Master) to DH+ is the optimal communication direction. This allows multiple AB Ethernet (CIP and 2222) devices to communicate to multiple DH+ nodes using the DataLink DL3500-DH+/IAP.

Datalink Solution: PLC-5 / SLC5/04 via DH+ to Ethernet!
Q:: How do I interface a legacy PLC-5 / SLC 5/04 via DH+ to AB’s Ethernet/IP or Ethernet TCP/IP? A: Our DL4500-EDH+ will allow RSlinx & RSLogix to access DH+ via Ethernet TCP/IP.
A:
Our DL3500-DH+/IAP will allow RSlinx & RSLogix to access DH+ via AB’s Ethernet/IP.

 

Allen Bradley Replacements - cost effective reliable and proven solutions.
AB 1770-KF2 Replacement Connect these devices  
DL3500-DH+/DF1 DF1 to DH+ Network (DH+ DF1). Alternative / Replacement for 1770-KF2, 1784-P(KTX) - (1784-PKTX, 1784-KTX), 1784-PCMK or SST 5136-SD.  
DL-PC/104 PC/104 Bus Interface  
DL-PC ISA Bus Interface  
DL-PCI PCI Bus interface  
     
AB 1770-KF3 Replacement    
DL3500-DH-485/DF1 DF1 to DH-485 Network (DH-485 DF1). Alternative / Replacement for 1770-KF3, 1784-P(KTX) - (1784-PKTX, 1784-KTX), 1784-PCMK or SST 5136-SD.  
DL-PC/104 PC/104 Bus Interface  
DL-PC ISA Bus Interface  
DL-PCI PCI Bus interface  
     
1784-PKTX Replacement    
DL3500-DH+/DF1 DF1 to DH+ Network (DH+ DF1). Alternative / Replacement for 1770-KF2, 1784-P(KTX) - (1784-PKTX, 1784-KTX), 1784-PCMK or SST 5136-SD.  
DL-PCI PCI Bus interface  
     
1784-PCMK Replacement    
DL3500-DH+/DF1 DF1 to DH+ Network (DH+ DF1). Alternative / Replacement for 1770-KF2, 1784-P(KTX) - (1784-PKTX, 1784-KTX), 1784-PCMK or SST 5136-SD.  
DL-PCI PCI Bus interface  
     
1784-KTX Replacement    
DL3500-DH+/DF1 DF1 to DH+ Network (DH+ DF1). Alternative / Replacement for 1770-KF2, 1784-P(KTX) - (1784-PKTX, 1784-KTX), 1784-PCMK or SST 5136-SD.  
DL-PCI PCI Bus interface  
     
Allen Bradley - Ethernet IP to DH+
Ethernet IP to DH+ Connect these devices  
DL3500-DH+/IAP PLC 5E on AB Ethernet 2222 can read/write files/tags to SLC 5/04 on DH+  
  PLC 5E on AB Ethernet 2222 can read/write files/tags to PLC 5 on DH+.  
  Micrologix on AB Ethernet/IP (via 1761-Net-ENI) can read/write files/tags to SLC 5/04 on DH+.  
  Micrologix on AB Ethernet/IP (via 1761-Net-ENI) can read/write files/tags to PLC 5 on DH+.  
  CompactLogix on AB Ethernet/IP (via 1761-Net-ENI) can read/write files/tags to SLC 5/04 on DH+.  
  CompactLogix on AB Ethernet/IP (via 1761-Net-ENI) can read/write files/tags to PLC 5 on DH+.  
  Flexlogix on AB Ethernet/IP (via 1761-Net-ENI) can read/write files/tags to SLC 5/04 on DH+.  
  Flexlogix on AB Ethernet/IP (via 1761-Net-ENI) can read/write files/tags to PLC 5 on DH+.  
  SLC 5/05 read/write files/tags to SLC 5/04 on DH+  
  SLC 5/05 read/write file/tags to PLC 5 on DH+  
     
DH+ Allen Bradley - Connect your device to DH+
DH+ connectivity Connect these devices  
DL4500-EDH+ Ethernet TCP/IP to DH+  
DL3500-DH+/IAP Ethernet IP to DH+  
DL3500-DH+/DF1
Replacement to AB 1770-KF2.

DF1 to DH+  
DL4500-MEDH+ Modbus TCP/IP to DH+  

DL3500-DH+/DF1
(Channel 0 DF1) Replacement to AB 1770-KF2. Provides the same functionality as the 1784-P(KTX), 1784-PCMK or SST 5136-SD.

SLC 5/02 to DH+ Com Port: DH-485  
DL3500-DH+/DF1
(Channel 0 DF1) Replacement to AB 1770-KF2. Provides the same functionality as the 1784-P(KTX), 1784-PCMK or SST 5136-SD.

SLC 5/03 to DH+ Com Port: DH-485 & RS-232T  
DL3500-DH+/DF1
(Channel 0 DF1) Replacement to AB 1770-KF2. Provides the same functionality as the 1784-P(KTX), 1784-PCMK or SST 5136-SD.

SLC 5/04 to DH+ Com Port: DH+ & RS-232T  
DL3500-DH+/DF1
(Channel 0 DF1) Replacement to AB 1770-KF2. Provides the same functionality as the 1784-P(KTX), 1784-PCMK or SST 5136-SD.

SLC 5/05 to DH+ Com Port: Ethernet & RS-232T  
DL-PCI PCI Bus Interface to DH+  
DL-PC/104 PC/104 Bus Interface to DH+ -PC/104 computers, MMIs, and OEM equipment  
DL-PC ISA Bus Interface to DH+  
     
RSLinx to DH+, DH-485 and Ethernet
- Connect to DH+ with DataLink product below: Connect to DH-485 with DataLink product below:  
Ethernet TCP/IP DL4500-EDH+ DL4500-EDH-485  
Ethernet IP DL3500-DH+/IAP DL3500-DH+/IAP  
DF1 DL3500-DH+/DF1 DL3500-DH-485/DF1  
 